graphic
Main 1
Not in use for the moment
Main 2
If only a few parameters need to be changed, this option allows the user to read the menus and insert the correct values. An index value is prompted, and after selecting the appropriate one the value of that index is given. A carriage return given as a value returns a null value. 
Main 3
Menu showing the simulation flags that control the program and allow the user to invoke or evoke certain types of simulation features. These flags are set/reset by typing the corresponding flag number. 
Main 4
Allow the user to export data to a named SMC file. For data transfer to multiple files, please refer to Option 10 within this section. Carriage return given at the file name prompter returns to the main menu without action. 
Main 5
Allow the user to import data from a SMC file previously stored. Carriage return given at the file name prompter returns to the main menu without action. 
Main 6
Allow the user to delete all information [parameter values] from  CHANGE [current SMC file] and begin from scratch. All detector parameters are set to zero and the simulation flags are all set to FALSE. 
Main 7
Allow the user to insert a comment about the individual simulation that then will appear in the result file [*.res] written by  SIMIND
Main 8
Allow the user to transfer current changes from an SMC file to other previously created SMC files. By simply invoking the wildcard command, the user has the possibility of controlling data transfer from one SMC file to whichever other SMC files are needed. The program prompts for [Y,N,A,Q]. "Y" means that changes will be transferred to the current file, "N" means no transfer, "A" means transfer without further confirmation [ALL] and "Q" means simply quit the option and return to MAIN MENU. The counter that keeps track of the changes is reset by either 
a] entering the program CHANGE
b] clearing all data by Index 8, or 
c] after a transfer by Index 10. 
Main 9
Tables of energy-dependent cross-sectional values for the photoelectric, Compton, coherent, and pair production interactions unique to the particular phantom, cover and crystal incorporated into SIMIND. The typical phantom cross section is water, given by the file h2o.cr3
Main 10
Tables of energy-dependent cross-sectional values for the photoelectric, Compton, coherent, and pair production interactions unique to the particular phantom, cover and crystal incorporated into SIMIND. The typical phantom cross section is water, given by the file h2o.cr3. This cross-section table is only used when simulating voxel-based phantoms. The cross-section is used for those voxel that have a density value higher than a particular threshold. This threshold is defined in the  simind.ini file. A typical cross-section table is bone.cr3 but also be the same as the selection in  Main 9.
Main 11
Tables of energy-dependent cross-section data for photoelectric, Compton, coherent, and pair production interactions unique to the particular cover material  incorporated into SIMIND. A typical cross- section material for this compartment is  al.cr3. 

Note: The use of a cover is determined by  Flag 10
  
Main 12
Tables of energy-dependent cross-sectional values for the photoelectric, Compton, coherent, and pair production interactions unique to the particular crystal incorporated into SIMIND. The crystal of the detector is typically sodium iodide and is denoted by the file name, nai.cr3
Main 13
Allow the user to input a name for a file that stores density maps for simulations of a non-homogeneous phantom. The file extension default is *.smi. 
Note: If you are using images created from MCAT or NCAT sofware you should only give the base name of the file. SIMIND adds the characters 'atn_av'. SIMIND adds the characters 'act_av'. It is assumed that the MCAT/NCAT file has the extension 'bin'
Main 14
Allow the user to input a name for a file that stores source maps for simulation of a 
nonhomogeneous source. Similarly, the file extension default is *.smi. The file name is given to SIMIND by the data file. 
Note: If you are using images created from MCAT or NCAT sofware you should only give the base name of the file. SIMIND adds the characters 'act_av'. It is assumed that the MCAT/NCAT file has the extension 'bin'
Main 15
Allow the user to input a file name for the back scattering media. This simulate the backscattering from light guides and PM tubes. The simulation is based on a solid material of equal size as the crystal but with a user- selected thickness. The thickness is given by Index 11 in MENU 2.The number of scatter orders is set in the  simind.ini  file.